I was also under the impression that if wiring is in an attic space that it may need to be derated because it can get very hot up there.
Running electrical wire through attic.
Yes this should be corrected and it would be good to have the wiring and all the circuit connections inspected as well.
Always turn off the breakers in your electrical box before you begin to reduce the chance of an electrical shock should you accidently cut or drill into existing wiring.
Make sure you use ul rated in wall wiring that meets local building and fire codes including cm cmr or cmp for computer networking and cl2 or cl3 for speakers.
Whenever i do attic wiring i remove the insulation and staple it to the ceiling joist.
When cutting through drywall from the interior of a room use a utility knife and cut carefully you don t want to drill through a hidden wire or the paper backing of the attic insulation.
And use semi rigid wiring fish tape to pull your wiring down to your outlet location.
Select proper wire or cable.
The problem is that my panel is on the exterior wall and the conduit will need to enter the attic space.
The attic wiring should be protected and secured to ceiling joists or other wood structural supports.
To run the wires inside rigid conduit you ll need a hacksaw a pipe bender capable of bending 1 2 in.
Cable can be fished through framing via access holes or through an unfinished basement or attic.
Running electrical cable inside finished walls starts with marking the framing and planning the best cable route.
The following links will assist you with your electrical question.
Turn off the power.
Hi all i have to run some romex in my attic.
I am running a couple of new circuits to the bathroom which will involve running thhn wires through the emt conduit.
If this meets code then i will be running attic wiring in this manner from now on.
These holes will be used to fish the cable down into the basement or crawlspace area or up into the attic in order to run the cable from box to box.
My attic is non accessible so i know for a fact that i must protect the romex with guard strips or bore holes 1 25 from the face of the joists when running perpendicular to the joists and when i run parallel i must staple the romex to the face of the joists.
Watch the entire process step by step.
If you will need to fish wiring through a wall drill a hole through the wood plate in the attic only.
Rigid conduit with an outside diameter of 3 4 in and a fish tape long enough to reach through the buried pipe.